Operating Controls
4. Wire PG, 4-pin plug (Calrad #30-453, RTS # 2013-0016-00) to the external supply: Pin 1 = common,
Pin 2 = external supply +.
5. Plug P6 into J6 on the RMS300 or SPK300L back panel.
NOTE: If using RTS local power option kit 9002-5541-00, the external supply will already be wired to P6. Obsolete products
have been discontinued and are no longer available for purchase.
When a system is constructed using locally powered user stations, it is essential that all channels are terminated with a 200
ohm system termination. System terminations (see diagram below) include:
An RTS System TW power supply *
A discrete 200 ohm resistor for each locally supplied channel
When application of a D.C. voltage is expected or possible, a 10 microfarad / 50 Volt capacitor in series with the 200 ohm
resistor for each locally supplied channel.
*Examples of RTS System power supplies are:
PS8, PS10, PS15, PS20, PS30, PS31, PS50, and PS60.
FIGURE 2. CC300 P.C. Board modifications.
FIGURE 3. Power Supply diagram
1
2
4
3
J6
Local Power
(Back Panel)
#22 AWG Wire
Remove D26
CC 300 P.C. Board