6
DIP Switches
DIP Switch 1: RVON-I/O Mode
Default Position: Open
Switch Position: Open - Local Mode
Closed - Remote Mode
Description: There are two (2) modes in which the RVON-I/O can run: local and remote mode
In Local mode, keypanels are directly connected to the RVON-I/O. For example, a KP-32 is
connected serially to the RVON-I/O which is connected via Ethernet to the RVON-8 in the
ADAM system. The connection between the KP-32 and the RVON-I/O is local.
In Remote mode, a digital keypanel (such as a KP-32 with RVON-1) is connected to an
RVON-I/O, which is then connected to an ADAM CS, Zeus, Cronus or an ADAM with AIO
cards.
NOTE: To see system drawing scenarios of both local and remote mode, see “System
Diagrams” on page 12
DIP Switch 2: Serial Debug Shell
Default Position: Open
Switch Position: Open - Pass-through port enabled
Closed - Serial Debug Shell enabled; IP configuration on Audio Port 8.
Description When the Dip Switch is closed, serial debug is enabled. When the Dip switch is open, the
pass-through port is enabled.
The Pass-through Port is used to send serial port data over Ethernet.
The Serial Debug Shell provides the user access to a command shell (this is similar to Telnet,
except the connection is made through a serial cable).
The IP configuration on I/O Port 8 allows users to connect and configure the IP Address of the
RVON-I/O using a compatible keypanel (KP-32, KP-632, KP-832, and KP-812) connected
serially to I/O Port 8 on the back of the RVON-I/O. IP Configurations are made from the
keypanel service menu. Note, you must have keypanel firmware version 2.02 or higher to
configure the IP Address.
DIP Switch 3: Telnet Shell
Default Position: OPEN
Switch Position: OPEN - Telnet Shell is enabled
CLOSED - Disabled, user name and password are set to default
Description Using telnet, you can set permissions and configurations within the RVON-I/O application. See
Table , “RVON-I/O Command Table,” on page 25.
DIP Switch 4: Boot Downloader
Default Position: Open
Switch Position: Open - Boot downloader is disabled (runs the native flash program)
Closed - Boot downloader is enabled (runs the boot downloader)
Description:
Switches to the boot downloader flash program. This program is sent with the RVON-I/O in case
the native flash program becomes corrupt.