adjust listen levels for intercom keys, you want to make sure that the MOD numbers for the level
control knobs match the MOD numbers for the intercom keys. The LCP MOD numbers cannot be
set from the KP-12, but rather, they must be set by replacing the internal read-only memory
(ROM) in the LCP. Table
4 shows the default MOD numbers that are programmed into the the vari-
ous LCP’s. Note that the default settings for LCP’s will work when one LCP-12 is used with a KP-
12, or when one LCP-16 or LCP-20 is being used with one EKP-16 or EKP-20. However, there are
two situations where you will need to change the ROM in an LCP: 1) when you want to use an
LCP-12 with an EKP-12; or 2) when you are connecting more than one EKP, and you want to use
LCP’s with each EKP. If you need to change MOD numbers in an LCP, contact your intercom dealer
for assistance.
To set up KP-12 and EKP MOD numbers refer to the “Procedure to Assign MODS”, below. For
examples see “Using Multiple Expansion Panels”, page
43.
7.5.6.2 Procedure to Assign MODS
☞
If the keypanel is currently displaying MD1 in the left side of the call waiting window, skip
steps 1 through 3.
1. Rotate the SELECT control to display MENUS, then click SELECT.
2. Rotate SELECT to display SERVICE, then click SELECT.
3. Rotate SELECT to display MOD ASGN, then click SELECT.
4. The currently assigned MOD numbers should now appear in the displays above the keys on
the keypanel (and any connected EKP’s connected to a KP-12). Also, MD1 will display in the
left side of the call waiting window. This signifies MOD1. The right side of the call waiting
window indicates where the module is currently assigned. One of the following will display:
MAIN Indicates the module is assigned to the keypanel.
EXP1 Indicates the module is assigned to the first expansion panel.
EXP2 Indicates the module is assigned to the second expansion panel.
NONE Indicates the module is not assigned.
5. Rotate the SELECT control until the MOD number that you want to assign (MD1, MD2 etc.)
is displayed in the left side of the call waiting window. Then, click the SELECT control.
6. Read this instruction completely before proceeding! Rotate the SELECT control to select the
panel where you want to assign the MOD, BUT DO NOT CLICK SELECT YET.
7. On the selected panel, identify the group of 4 keys where you want to assign the MOD. Press
and hold any one of these 4 keys, then click the SELECT control. After a few moments, the
new MOD number should appear in the displays above the affected keys (if it was not
displayed before) and the call waiting window will confirm that the MOD has been assigned
as requested by displaying the MOD number and the panel where it was assigned.
8. Double-click SELECT to return to the previous menu level, then repeat from step 5 to assign
additional MODs. Or, press and hold the SELECT control for about two seconds to exit menu
mode.
☞
MOD changes are saved automatically. You do not need to run SAVE CFG.